annaite

CHANGZHOU ANYTE CABLE CO.,LTD

ANYTE CABLE, MULTICORE CABLE, UL CABLE,

TUV CE H05Z1-K H07Z1-K

TUV CE H05Z1-K H07Z1-K

TUV CE H05Z1-K H07Z1-K

♦Fire Resistant

♦Temperature : 70℃

♦Voltage: 300/500V , 450/750V

♦No smoke & Halogen-free 

♦Environmental friendly

Precautions for high-quality H07Z-K cables

Proper Installation: The installation of H07Z-K cables is crucial for ensuring their longevity and optimal performance. It is essential to follow the manufacturer’s instructions regarding the installation process. This includes guidelines for cable routing, securing, and termination. It is important to use appropriate cable brackets or supports to prevent stress on the cables and ensure they are not subjected to excessive tension or bending.
Overloading: H07Z-K cables have a maximum load capacity specified by the manufacturer. It is crucial to adhere to these load limits to prevent overloading the cables. Exceeding the maximum load capacity can cause the cables to overheat, leading to insulation deterioration, loss of performance, and potentially posing a fire hazard. It is necessary to accurately calculate the electrical load requirements and ensure that the cables are appropriately sized for the intended application.
Environmental Factors: H07Z-K cables should be protected from various environmental factors that can potentially damage or degrade their performance. Exposure to UV rays can cause the cable insulation to degrade over time, leading to decreased electrical insulation properties. Therefore, it is important to install the cables in areas shielded from direct sunlight or use UV-resistant cable conduits or covers.

Moisture can also negatively impact the performance and lifespan of the cables. Therefore, proper measures should be taken to protect the cables from moisture ingress, such as using moisture-resistant cable glands or conduits. In environments where chemicals are present, it is essential to select cables with appropriate chemical resistance properties or provide additional protective measures to prevent chemical damage.

Cables should be safeguarded against physical damage as well. They should be installed away from sharp edges, moving machinery, or areas where they can be pinched or crushed. Cable trays, conduits, or protective covers can be utilized to shield the cables from potential physical hazards.

Maintenance: Regular maintenance of H07Z-K cables is important to ensure their continued performance and longevity. This includes visually inspecting the cables periodically to check for any signs of damage, such as cuts, abrasions, or exposed conductors. If any damage is detected, immediate repairs or replacements should be carried out.

Cleaning the cables, particularly in industrial or outdoor environments, is beneficial to remove dirt, dust, or other contaminants that can accumulate over time. However, it is important to use appropriate cleaning methods and avoid using harsh chemicals that could damage the cable insulation.

The considerations for H07Z-K cables include proper installation according to the manufacturer’s instructions, avoiding overloading, protecting the cables from environmental factors such as UV rays, moisture, and chemicals, and conducting regular maintenance to ensure their longevity and performance. Adhering to these considerations will help maximize the lifespan and reliability of the H07Z-K cables in various applications.
In conclusion

High quality H07Z-K cables and high performance RV-K cables etc. are ideal for a variety of electrical applications including power and lighting, industrial equipment, and building wiring. These cables are designed to provide high-quality performance, reliable power transmission, and are highly flexible and durable. When used properly, H07Z-K cables provide long-lasting and efficient power transmission for a variety of applications. However, it is important to follow the manufacturer’s instructions and precautions for proper installation, use and maintenance to ensure their longevity and performance.

 

1. Introduction of TUV / CE H05Z1-K / H07Z1-K

TUV / CE H05Z1-K / H07Z1-K  is a halogen-free single-core wire, suited to be installed in dry or wet indoor environments for wiring of lighting fixtures and wiring in the fire protection to prevent damage to valuable property and equipment must be carried out. Can be connected to the lights, equipment, switchgear, power distribution box. Can be used in densely populated or valuable equipment of buildings, but also for public or private transport, the single-core wire can be installed on the casing, or stucco. Welcome to inquiry. 

 

2. Parameter (Specification) of TUV / CE H05Z1-K / H07Z1-K

Description

TUV / CE H05Z1-K / H07Z1-K

Conductor:

      stranded fine bare copper or tinned copper wire  

Insulation:

LSZH

Insulation Color

               As requested

Rated Temperature

70℃

Rated voltage:

300/500V , 450/750V

Test Voltage:

2000 V

Minimal Bending Radius:

  8D  

Standard

EN 50525

 

Technical Data

Conductor

style

Conductor

Insulation

20 ℃ conductor resistance

 

Standard
Section

 

Wire/diameter

diameter

Nominal
Thickness

 

Nominal diameter

Max.diameter

 

 

No./mm

mm

mm

mm

mm

Ω/Km

stranded

0.5

16/0.20

0.92

0.6

2.12

2.6

39

0.5

28/0.15

0.92

0.6

2.12

2.6

39

0.75

24/0.20

1.13

0.6

2.33

2.8

26

0.75

42/0.15

1.13

0.6

2.33

2.8

26

1.0

32/0.20

1.3

0.6

2.5

3

19.5

1.5

48/0.20

1.6

0.7

3

3.5

1.5

30/0.25

1.58

0.7

2.98

3.5

2.5

49/0.25

2.02

0.8

3.62

4.2

2.5

77/0.20

2.03

0.8

3.63

4.2

4

56/0.30

2.6

0.8

4.2

4.8

6

84/0.30

3.18

0.8

4.78

6.3

10

84/0.40

4.23

1

6.23

7.6

16

126/0.40

5.88

1

7.88

8.8

25

196/0.40

7.7

1.2

9.48

10.2

35

276/0.40

8.8

1.2

10.95

11.7

50

396/0.40

10.8

1.4

12.63

13.9

70

360/0.50

12.7

1.4

14.53

16.0

95

475/0.50

15

1.6

16.99

18.2

120

608/0.50

16.8

1.6

18.69

20.2

150

764/0.50

18.3

1.8

21.70

22.5

185

925/0.50

21.1

2.0

24.3

25.1

240

1120/0.50

22.5

2.0

27.7

28.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A multicore H07Z-K cable is a cable that contains multiple individual wires or conductors within a single outer sheath. These cables are used in a variety of applications including industrial, commercial and residential environments.

One of the main advantages of multi-conductor H07Z-K cables is their ability to transmit multiple signals or power simultaneously. This increases efficiency and saves costs because multiple cables do not have to be run separately. They are also more flexible and more resistant to damage than single core cables.

Multi-core H07Z-K cables can be divided into two categories: shielded and unshielded. Shielded cables have an extra layer of insulation around the individual wires to help protect against electromagnetic interference (EMI) and radio frequency interference (RFI). Unshielded cables do not have this extra layer of insulation.

Another classification is based on the number of cores or wires inside the cable. The most common multi-core cables have two or four cores. However, depending on the application, some cables may have hundreds of cores.

Multicore H07Z-K cables are commonly used in a wide range of industries including telecommunications, transportation, power generation and manufacturing. They are also used in residential and commercial settings such as homes and office buildings.

The selection of multi-core H07Z-K cables depends on the specific application and the requirements of the cable use environment. Factors such as temperature range, frequency, and power requirements need to be considered when selecting the appropriate cable.

Overall, the H07Z-K cable is a versatile and efficient choice for transmitting multiple signals or power. With their many advantages and wide range of applications, they are an important part in many electrical systems.

3. Feature of the H05Z-K / H07Z-K

 1)Flexible, small bend radius, flame retardant
2) Combustion of low smoke does not produce toxic substances, the maximum guarantee the personnel safety of life
3) CE / TUV / VDE approval in line with European standards, so that the cable can be used in the European market at the same time.

 

4. Detail of the  H05Z-K / H07Z-K

 

1) Comply with multiple standards such as CE & TUV approved.
2) ROHS2.0 & REACH
3) Particular resistant to oil , chemical , small bend radius, flame resistance, ozone resistance
4) Brand: Anyte

 

5. Packaging & Delivery

 

1) Packaging Details:

It is determined by the quantity and requirements you purchase.  Can be negotiated.

 

2) Port: any port in China, Shanghai  Ningbo is better.

 

Delivery: vessel , Airplane or express.

 

6. FAQ

      Q: Why should choose your company for business partner?

A: (1) We have 10+ years of cable manufacture and export exprience, and complete certificates for cables.

     (2) Our R&D capability is strong and our staffs are well trained and skilled.

     (3) We have complete quality for material and production. Steady and qualified material suppliers.

     (4) Quick response for quotation or customer service.

 

     Q: What’s the difference between PVC cable and LSZH cable?

A: PVC material contains halogen, while LSZH is halogen-free. So when fired,  PVC release more and harmful smoke. LSZH is low smoke and halogen free smoke.  In public places, such as airports, and supermarkets, mostly choose LSZH cable, not PVC cable.

  • Q: What is your sample policy?

A: We can supply the sample for testing to check quality, but the customers need to pay the courier cost.

Related Products

TUV CE H03VVH2-F H05VVH2-F

Read More →

MTW / TEW Wire Single Core

Read More →

PVC Single Core Cable

Read More →
afb37fa8484e02be0ac10e7a0f81222 1661152211100 1

PVC insulated power cable

Read More →