Anaíta

CHANGZHOU ANYTE CABLE CO., LTD

CABLE ANYTE, CABLE MULTINÚCLEO, CABLE UL,

RHH RHW RHW-2

RHH RHW RHW-2

RHH RHW RHW-2

Conductor: Cobre desnudo
♦ Aislamiento: Polietileno reticulado (XLPE)
♦ Color del aislamiento: Colores o negro con número.
♦ Temperatura : 90℃
Tensión nominal: 600 V

1. Introducción de RHH / RHW / RHW-2 Cable

RHH / RHW / RHW-2 cables are underground Service Entrance Cable. 600 Volt. Copper conductors. Cross-Linked Polyethylene (XLP) Insulation. High-Heat, Moisture, and Sunlight Resistant. Sizes 6  through 4/0 AWG Also Rated SIS. They are used with conduit as specified in the 2011 National Electrical Code. When used as Type USE-2, conductor is suitable for use as underground service entrance cable for direct burial at conductor temperatures not to exceed 90° C. When used as RHH, conductor temperatures shall not exceed 90°C in dry locations. When used as RHW-2 or USE-2, conductor temperatures shall not exceed 90°C in wet or dry locations. Voltage rating for RHH or RHW-2 or USE-2 conductors is 600 volts.Welcome to inquiry. 

 

2.Parámetro (Especificación) de RHH / RHW / RHW-2 Cable

Descripción

RHH / RHW / RHW-2

Conductor:

  stranded fine bare copper   

Aislamiento:

Cross-Linked Polyethylene (XLPE)

Color del aislamiento

 Asolicitud de seducar

Temperatura nominal

  90℃

Tensión nominal:

600 V

Voltaje de prueba:

3000V

Radio de curvatura mínimo:

  8D  

Estándar

   UL44   

Datos técnicos

    AWG

Conductor O.D.

Grosor del aislamiento

Diámetro exterior del cable

INCH/MM

INCH/MM

INCH/MM

14

0.07

1.78

0.045

1.14

0.17

4.32

12

0.09

2.29

0.045

1.14

0.19

4.83

10

0.12

3.05

0.045

1.14

0.21

5.33

8

0.15

3.81

0.06

1.52

0.27

6.86

6

0.18

4.57

0.06

1.52

0.31

7.87

4

0.23

5.84

0.06

1.52

0.36

9.14

 

3.Característica de la RHH / RHW / RHW-2 Cable

 1)Abrasion, moisture, heat, and sunlight resistant 
2) ROHS2.0 & REACH Compliant
3)UL Standard 44 for RHH or RHW-2 ; UL Standard 854 for USE-2

 

 

4.Detalle de la RHH / RHW / RHW-2 Cable

 

1) When used as Type USE-2, conductor is suitable for use as underground service entrance cable for direct burial at conductor temperatures not to exceed 90° C.
2) When used as RHH, conductor temperatures shall not exceed 90°C in dry locations
3) When used as RHW-2 or USE-2, conductor temperatures shall not exceed 90°C in wet or dry locations
4) Marca: Anyte

5 Embalaje y Entrega

 

1) Detalles de empaquetado:

Está determinado por la cantidad y los requisitos que compre. Se puede negociar.

 

2) Puerto: SHANGHÁI, NINGBO

 

Entrega: por mar, por aire, por expreso.

 

6 preguntas frecuentes

Q:  What is XLPE material?

A:   XLPE or Cross-linked polyethylene is a thermoset insulation material. Crosslinking polymers is a process which changes the molecular structure of the polymer chains so that they are more tightly bound together and this crosslinking is done either by chemical means or physical means.

 

P: ¿Por qué debería elegir su empresa como socio comercial?

R: (1) Tenemos más de 10 años de experiencia en la fabricación y exportación de cables, y certificados completos para cables.

     (2) Nuestra capacidad de I+D es sólida y nuestro personal está bien capacitado y calificado. 

     (3) Tenemos calidad completa para material y producción. Proveedores de material estables y calificados.

     (4) Respuesta rápida para cotización o servicio al cliente.

 

Productos relacionados

bs6231 Cable Tri Rated

BS6231 Cable trifásico

Leer más →

cable espiral

Leer más →
UL3271

Cable UL3271

Leer más →

AWM UL20234

Leer más →