annaite

CHANGZHOU ANYTE CABLE CO., LTD

CÂBLE ANYTE, CÂBLE MULTIPOLAIRE, CÂBLE UL,

RHH RHW RHW-2

RHH RHW RHW-2

RHH RHW RHW-2

Conducteur : Cuivre nu
Isolation : Polyéthylène réticulé (XLPE)
Couleur d'isolation : couleurs ou noir avec numéro
Température : 90℃
Tension nominale : 600 V

1. Présentation de RHH / RHW / RHW-2 Cable

RHH / RHW / RHW-2 cables are underground Service Entrance Cable. 600 Volt. Copper conductors. Cross-Linked Polyethylene (XLP) Insulation. High-Heat, Moisture, and Sunlight Resistant. Sizes 6  through 4/0 AWG Also Rated SIS. They are used with conduit as specified in the 2011 National Electrical Code. When used as Type USE-2, conductor is suitable for use as underground service entrance cable for direct burial at conductor temperatures not to exceed 90° C. When used as RHH, conductor temperatures shall not exceed 90°C in dry locations. When used as RHW-2 or USE-2, conductor temperatures shall not exceed 90°C in wet or dry locations. Voltage rating for RHH or RHW-2 or USE-2 conductors is 600 volts.Welcome to inquiry. 

 

2.Paramètre (Spécification) de RHH / RHW / RHW-2 Cable

Description

RHH / RHW / RHW-2

Conducteur:

  stranded fine bare copper   

Isolation:

Cross-Linked Polyethylene (XLPE)

Couleur d'isolation

 UNla demandeéd

Température nominale

  90

Tension nominale:

600 V

Tension d'essai :

3000V

Rayon de courbure minimal :

  8D  

Standard

   UL44   

 

 

données techniques

    AWG

Conductor O.D.

Épaisseur d'isolation

Câble OD

INCH/MM

INCH/MM

INCH/MM

14

0.07

1.78

0.045

1.14

0.17

4.32

12

0.09

2.29

0.045

1.14

0.19

4.83

10

0.12

3.05

0.045

1.14

0.21

5.33

8

0.15

3.81

0.06

1.52

0.27

6.86

6

0.18

4.57

0.06

1.52

0.31

7.87

4

0.23

5.84

0.06

1.52

0.36

9.14

 

 

3. Caractéristique de la RHH / RHW / RHW-2 Cable

 1)Abrasion, moisture, heat, and sunlight resistant 
2) ROHS2.0 & REACH Compliant
3)UL Standard 44 for RHH or RHW-2 ; UL Standard 854 for USE-2

 

 

4.Détail de la RHH / RHW / RHW-2 Cable

 

1) When used as Type USE-2, conductor is suitable for use as underground service entrance cable for direct burial at conductor temperatures not to exceed 90° C.
2) When used as RHH, conductor temperatures shall not exceed 90°C in dry locations
3) When used as RHW-2 or USE-2, conductor temperatures shall not exceed 90°C in wet or dry locations
4) Marque : Tout

 

5 Emballage et livraison

 

1) Détails d'emballage :

Il est déterminé par la quantité et les exigences que vous achetez. Peut être négocié.

 

2) Port : SHANGHAI, NINGBO

 

Livraison : par mer, par avion, par exprès.

 

6 FAQ

 

Q:  What is XLPE material?

A:   XLPE or Cross-linked polyethylene is a thermoset insulation material. Crosslinking polymers is a process which changes the molecular structure of the polymer chains so that they are more tightly bound together and this crosslinking is done either by chemical means or physical means.

 

Q : Pourquoi choisir votre entreprise comme partenaire d'affaires ?

A: (1) nous avons plus de 10 ans d'expérience dans la fabrication et l'exportation de câbles, et des certificats complets pour les câbles.

     (2) Notre capacité de R&D est forte et notre personnel est bien formé et qualifié. 

     (3) Nous avons une qualité complète pour le matériel et la production. Fournisseurs de matériaux stables et qualifiés.

     (4) Réponse rapide pour un devis ou un service client.

 

N'importe quel câble

 

 

Produits connexes

AWM UL20233

En savoir plus →

TUV CE H05V-K H07V-K

En savoir plus →

Câble d'irrigation

En savoir plus →
acheter câble UL

UL3266

En savoir plus →