Instrumentation Cable

♦ Cooper Conductor of Class 5/6 (Stranded)
♦ PVC /XLPE Insulation, Twisted Pairs
♦ individual / Overall Shield: AL Foil+Drain Wire Shield ,   Braid Shield  
♦ PVC / LSZH Jacket
♦ Temperature Range:-10 —- +70℃
♦ Nominal Voltage: 300/500V , 450/750 V

♦Certification: UL / CE /CUL /CSA

1. مقدمة Instrumentation Cable 

Twisted Pairs Instrumentation cables are single or multi-pairs to carry signals. They are used for connecting instruments and electrical equipments , transducer-generate signals are transmitted through to panels, controllers and other devices.Welcome to inquiry. 

 

2. المعلمة (المواصفات) من Instrumentation Cable  

 

وصف

Instrumentation Cable

موصل:

موصل نحاسي مجدول من الفئة 5/6 (مرن)  

عازلة:

PVC  /  XLPE

 عازلة 

Pairs or Triples

طَوّق

شريط PET مغطى.

درع:

Individual +Collective

(معلب) نحاسي تدريع ، تغطية جديلة 85%

غمد

PVC / LSZH

غمد اللون

أسود ، رمادي أو حسب الطلب

درجة الحرارة المقدرة

 70

الفولطية:

300/500 فولت ,  450/750 فولت

اختبار الجهد:

2500 فولت

الحد الأدنى من نصف قطر الانحناء:

  8 د  

 

معلومات تقنية

Core No.*sq  mm²

كابل appr. التطوير التنظيمي

  مم

النحاس الوزن

   Kg/km

الوزن الموافق للكابل

   Kg/km

2 × 2 × 0،5

8.6

48.1

93

3 × 2 × 0،5

8.7

73.7

129

4 × 2 × 0،5

9.4

82.0

146

6 x 2 x 0,5

11.1

110.0

198

2 x 2 x 0,75

8.5

64.6

106

3 x 2 x 0,75

9.4

84.0

140

4 x 2 x 0,75

10.7

108.0

179

5 x 2 x 0,75

11.1

126.0

215

2 x 2 x 1

10.3

84.0

142

3 x 2 x 1

10.4

96.0

173

4 x 2 x 1

11.3

121.0

212

5 x 2 x 1

11.8

161.0

266

2x2x1.5

12.4

112.0

165.0

3 x2x1.5

13.0

140.0

218.0

4 x2x1.5

13.3

176.0

265.0

5 x2x1.5

15.5

212.0

310.0

 

3. ميزة Instrumentation Cable

 

Instrument cable is a specialized cable with many features and functions that make it widely used in industry and automation. Here are some of the key features of instrument cables:

  • Twisted pair structure: Instrument cables usually use twisted pair structure. This construction helps reduce electromagnetic interference (EMI) from external sources by interweaving two insulated conductors. This is critical to maintaining signal stability and accuracy, especially in applications requiring precision measurements.

 

  • Shielding structure: Instrument cables can have different types of shielding structures to meet different signal transmission needs. The structure of individually shielded pairs is often used to transmit analog signals to minimize external interference. The structure with only overall shielding is usually used to transmit digital signals, because digital signals are more resistant to interference than analog signals.

 

  • Immunity: Instrument cables are designed to minimize crosstalk. This means that the signal can remain clear and stable even in complex electromagnetic environments. This is critical to ensure data accuracy and reliability, especially in the fields of industrial automation and process control.

 

  • Corrosion Resistance: Since instrumentation cables are often used in industrial environments, they often have corrosion-resistant properties. This means they can be used in locations with corrosive gases or chemicals for extended periods of time without damage.

 

  • High Temperature Resistance: Some applications require cables to withstand high temperature environments, such as refining processes in the oil and gas industry. Therefore, instrument cables often have high-temperature resistant properties to ensure their reliability under extreme conditions.

 

  • Diverse Application Areas: Typical application areas for instrumentation cables include process industries such as oil and gas production, chemical and petrochemical plants, water treatment facilities, and the mining industry. In addition, they are also widely used in any factory and equipment that requires automation and precision control to ensure process stability and efficiency.

In summary, the features of instrumentation cables including their twisted pair construction, different types of shielding, immunity to interference, resistance to corrosion and resistance to high temperatures make it a preferred choice in industry and automation. These features ensure reliable transmission of data and signals, helping to increase the accuracy and efficiency of industrial processes.

 

4. تفاصيل ملف Instrumentation Cable 

 

 1) Pairs: Twisted or Triple
2) Individual Screen: Aluminium / PETP tape over tinned copper drain wire, plastic tape under and above screen
3) Collective Screen: Aluminium / PETP tape over tinned copper drain wire, plastic tape under and above screen
4) العلامة التجارية: أنيت

 

 

5 التغليف والتسليم

 

1) تفاصيل التغليف:

يتم تحديده حسب الكمية والمتطلبات التي تشتريها. يمكن التفاوض عليها.

 

2) المنفذ: شنغهاي ، نينغبو

 

التسليم: عن طريق البحر ، عن طريق الجو ، عن طريق التعبير.

 

6 أسئلة وأجوبة:

 

ما هو وقتك الرصاص للبضائع السائبة؟

أ: بصراحة ، يعتمد ذلك على كمية الطلب ومواد الكابلات. المهلة العادية حوالي 2-3 أسابيع.

 

س: كيف تضمن الجودة؟

أ: نحن شركة معتمدة من UL / TUV / CSA / SAA / ISO9000.1. جميع المواد لدينا هي RoHS 2.0. عند الإنتاج ، يكون مفتش كل خطوة على فحص التوجيه، و اختبار 100% قبل التسليم.

 

منتجات ذات صله

H05Z1Z1-F

H03Z1Z1-F H05Z1Z1-F

اقرأ المزيد →

Instrumentation Cable

اقرأ المزيد →

CE CU XLPE SWA PVC Power Cable

اقرأ المزيد →
كابل مقاوم للحريق

كابل مقاوم للحريق

اقرأ المزيد →